HomeDocumentationRecipesChangelog
HomeRequest DemoContact
Documentation
HomeRequest DemoContact

Configuring Difference Thresholds

Difference thresholds monitor a metric and alerts when the difference of the metric value between windows deviates from a specified absolute value or percentage value for consecutive windows.

The following table lists the parameters for configuring a difference threshold. Configuration options differ depending on the type of validator.

Parameter NameParameter ValueValidator Type
Difference TypeAbsolute
Percentage
All
OperatorDecreasing (<=)
Increasing (>=)
Strictly decreasing (<)
Strictly increasing (>)
All
UnitSecond
Minute
Hour
Day
Week
Month
Year
Freshness
Relative Time
ValueNumeric value. For absolute, the value is in the scale of the metric. For percentage, the value is the percentage points.All
Number of WindowsNumber of consecutive windows for which the threshold event must happen before an incident is created.All