Configuring Difference Thresholds

Difference thresholds monitor a metric and alerts when the difference of the metric value between windows deviates from a specified absolute value or percentage value for consecutive windows.

The following table lists the parameters for configuring a difference threshold. Configuration options differ depending on the type of validator.

Parameter Name

Parameter Value

Validator Type

Difference Type

Absolute
Percentage

All

Operator

Decreasing (<=)
Increasing (>=)
Strictly decreasing (<)
Strictly increasing (>)

All

Unit

Second
Minute
Hour
Day
Week
Month
Year

Freshness
Relative Time

Value

Numeric value. For absolute, the value is in the scale of the metric. For percentage, the value is the percentage points.

All

Number of Windows

Number of consecutive windows for which the threshold event must happen before an incident is created.